胶体(dryfit)A400系列电池是把电解液固定于胶体中的密闭阀控式铅酸可充电电池。胶体技术由德国阳光公司发明并发展。实现了电池免维护。它析气量低,经久耐用,长达12年的设计寿命,以及实际的运行经验证明了它的高度可靠性。 胶体(dryfit)A400系列电池可用于多种用途,诸如:通讯、发电、配电、遥控及交通工程、保安电力供应、数据工程系统、报警讯号及安全照明等。
|
|
型号
|
编号
|
电压
|
C10
1.80
VpC
20℃
Ah
|
短路电流
(IEC896/2)
|
长
mm
|
宽
mm
|
高
mm
|
高
(含顶盖)
mm
|
高
(含端子)
mm
|
重量
Kg.
|
内阻
(IEC896/2)
mOhm
|
**负载
A
|
**短路电流
(5秒)
A
|
端子
|
A412/65 G6
|
NGA4120065HS0BA
|
12
|
65
|
1414
|
353
|
175
|
190
|
190
|
190
|
24.6
|
9
|
440
|
1500
|
G-M6
|
恒电流放电参数表(20℃ 安培)
编号
|
型号
|
电压
|
5min
|
10min
|
15min
|
20min
|
30min
|
45min
|
1h
|
2h
|
3h
|
4h
|
5h
|
8h
|
10h
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.85
|
102.0
|
77.0
|
63.0
|
56.0
|
48.0
|
42.0
|
36.0
|
22.0
|
15.9
|
12.9
|
10.9
|
7.3
|
6.2
|
NGA4120065HS0BA
|
A412/65G6
|
1.80
|
120.0
|
95.0
|
76.0
|
64.0
|
52.0
|
45.0
|
39.0
|
23.0
|
16.7
|
13.4
|
11.3
|
7.6
|
6.5
|
NGA4120065HS0BA
|
A412/65G6
|
1.75
|
134.0
|
107.0
|
84.0
|
70.0
|
56.0
|
48.0
|
41.0
|
24.0
|
17.1
|
13.6
|
11.4
|
7.7
|
6.5
|
NGA4120065HS0BA
|
A412/65G6
|
1.70
|
148.0
|
111.0
|
89.0
|
73.0
|
57.0
|
49.0
|
41.0
|
24.0
|
17.3
|
13.7
|
11.5
|
7.7
|
6.5
|
NGA4120065HS0BA
|
A412/65G6
|
1.65
|
161.0
|
114.0
|
91.0
|
75.0
|
57.0
|
49.0
|
42.0
|
24.0
|
17.3
|
13.7
|
11.5
|
7.7
|
6.5
|
NGA4120065HS0BA
|
A412/65G6
|
1.60
|
170.0
|
116.0
|
92.0
|
76.0
|
58.0
|
49.0
|
42.0
|
24.0
|
17.3
|
13.8
|
11.5
|
7.7
|
6.5
|
恒功率放电参数表(20℃ 瓦/单体)
编号
|
型号
|
电压
|
2min
|
3min
|
5min
|
7min
|
10min
|
15min
|
20min
|
30min
|
45min
|
1h
|
2h
|
3h
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NGA4120065HS0BA
|
A412/65G6
|
1.85
|
1,440.0
|
1,342.0
|
1,221.0
|
1,137.0
|
1,025.0
|
867.0
|
759.0
|
635.0
|
482.0
|
396.0
|
239.0
|
175.0
|
NGA4120065HS0BA
|
A412/65G6
|
1.80
|
1,702.0
|
1,601.0
|
1,430.0
|
1,296.0
|
1,158.0
|
977.0
|
834.0
|
690.0
|
516.0
|
420.0
|
260.0
|
190.0
|
NGA4120065HS0BA
|
A412/65G6
|
1.75
|
1,968.0
|
1,830.0
|
1,620.0
|
1,447.0
|
1,268.0
|
1,054.0
|
886.0
|
714.0
|
534.0
|
432.0
|
270.0
|
193.0
|
NGA4120065HS0BA
|
A412/65G6
|
1.70
|
2,191.0
|
2,009.0
|
1,762.0
|
1,570.0
|
1,323.0
|
1,100.0
|
916.0
|
723.0
|
541.0
|
437.0
|
270.0
|
194.0
|
NGA4120065HS0BA
|
A412/65G6
|
1.65
|
2,419.0
|
2,214.0
|
1,874.0
|
1,658.0
|
1,371.0
|
1,125.0
|
932.0
|
727.0
|
545.0
|
439.0
|
271.0
|
195.0
|
NGA4120065HS0BA
|
A412/65G6
|
1.60
|
2,603.0
|
2,402.0
|
1,962.0
|
1,713.0
|
1,400.0
|
1,137.0
|
940.0
|
729.0
|
547.0
|
440.0
|
272.0
|
196.0
|
|
定期充电放电。UPS电源系统中的浮充电压和放电电压,在出厂时均已调试到额定值,而放电电流的大小是随着负载的增大而增加的,使用中应合理调节负载,比如控制计算机等电子设备的使用台数。一般情况下,负载不宜超过UPS额定负载的60%。在这个范围内,蓄电池就不会出现过度放电。
UPS因长期与市电相连,在供电质量高、很少发生停电的使用环境中,蓄电池会长期处于浮充电状态,时间长了就会造成电池化学能与电能相互转化的活性降低,加速老化而缩短使用寿命。因此,一般每隔2~3个月应完全放电一次,放电时间可根据蓄电池的容量和负载大小确定。一次全负荷放电完毕后,按规定再充电8小时以上。
**产品:(免维护蓄电池,汤浅蓄电池,德国阳光蓄电池,山特蓄电池,赛特蓄电池,美国APC蓄电池,松树蓄电池,OTP蓄电池,**蓄电池,山顿蓄电池)